Control Board - ICM ICM281
Control Board CM281
Replaces the following Carrier Boards
CES0110057-00,CES0110057-01, CES0110057-02,HH84AA016
Direct replacement board for Carrier CESO11005700/01/02
- Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner
- Microprocessor-based for precise timing
- Functions with all 24 VAC thermostats
- Designed for 100% gas shutoff in case of ignition failure
- Twinning compatible with another ICM281 board
- Reverse polarity protection
- Secondary brownout voltage protection
- Diagnostic fault codes (blinking LED) for simple troubleshooting
Specifications
Environment:
Ambient Temperature
- Operating: -40ºF to 176ºF
- Storage: -40ºF to 185ºF
Humidity: 5% to 95% R.H. (non-condensing) @ +55ºF
Electrical:
Voltage Range: Line (98 to 132 VAC) @ 60Hz
Ignitor: 5A @ 120 VAC
Cool Blower: 30A, 2 HP, 240 VAC
Heat: 5A, 1/2 HP, 240 VAC
Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
Gas Valve: 1.5A @ 30 VAC